We plan to place the loop cable in a ceiling with acoustic ceiling tiles (60x60cm) – does that work?
To achieve a good result the cable has to be placed in the middle of the tiles, not close to the metallic frame. You should not place the cable at a height above 3m.
We plan to place the loop at floor level in a room 10x5m, where shall I place the loop cable?
Always start with a 2-turn loop. If you do not reach an acceptable field strength level, try with a 1-turn loop. In small premises like this, the 2-turn loop will probably give the best result.
How shall I do to splice the copper foil cable?
We recommend to solder the cable. It is also possible to splice with standard cable as long as the area is the same as the area of the copper foil cable.
Which type of cable do you recommend?
To get a high flexibility we recommend to use 2x2,5mm² in most installations. Always start with a 2-turn loop. If you do not reach an acceptable field strength level, try with a 1-turn loop.
I need to install a loop in a church, and it is not possible to place a loop in the floor. What can I do?
It is possible to place the loop cable outside the church walls. Please contact us for more detailed information.